Ra to Rz Conversion
Estimate an Ra/Rz screening range
Ra and Rz describe different aspects of a measured surface profile. They are not interchangeable units, so no equation can recover one exact parameter from the other without the original profile data.
Use this tool to create a screening range for preliminary quoting or clarification when an approximately Gaussian random profile is a reasonable assumption. For a drawing, purchase order or inspection decision, specify and measure the parameter required by the governing standard.
Ra ↔ Rz Screening Estimator
Do not copy the estimated parameter into a drawing or inspection plan as an exact equivalent.
Why the range is wide
This model uses Rz ≈ 5–10 × Ra when an approximately Gaussian random profile is a reasonable assumption. NIST describes this order-of-magnitude relationship in its surface-calibration discussion; it is not a statistical confidence interval. The actual relationship changes with the surface profile, process, filtering, sampling/evaluation conditions, instrument and governing definition. For periodic tool marks or other profiles, measure the required parameter. An estimated Rz does not establish compliance with an Ra drawing requirement.
Specify parameter + value + unit + governing standard and measurement conditions. ISO 21920-2:2021 defines current ISO profile parameters; ASME B46.1 covers surface texture terminology and specification in US practice.
Enter a positive Ra or Rz value in µm or µin. The tool converts units, then applies the Gaussian random-profile model Rz ≈ 5–10 × Ra, or Ra ≈ Rz/10 to Rz/5. For periodic tool marks or other profiles, measure the required parameter.
Ra vs Rz: What You’re Actually Comparing
Ra — arithmetic mean height
Ra averages the absolute profile-height deviations over the defined evaluation procedure. It is useful for describing overall profile amplitude but can hide isolated peaks and valleys.
Rz — maximum height of the roughness profile under the governing definition
Rz is based on peak-to-valley profile extremes and is more sensitive to local features. Legacy DIN/JIS documents may use definitions or symbols that are not identical to current ISO practice.
Key point: two surfaces can have the same Ra and different Rz. Confirm which standard and edition the drawing uses before comparing values.

Why You Should Use a Range (Not One Fixed Number)
The Rz/Ra relationship changes with the shape and distribution of peaks and valleys. It is influenced by:
- manufacturing process and resulting profile;
- filtering and nesting-index/cutoff choices;
- sampling and evaluation conditions;
- instrument, stylus and measurement direction; and
- the governing definition used for Rz.
Therefore, a broad ratio is useful only to flag whether two stated values are plausibly in the same order of magnitude. It cannot certify equivalence.
Gaussian Random-Profile Screening Examples
The Gaussian random-profile screening model uses Rz ≈ 5–10 × Ra; in reverse, Ra ≈ Rz/10 to Rz/5.
| Input | Gaussian-model screening output |
|---|---|
| Ra 0.2 µm | Rz about 1.0–2.0 µm |
| Ra 0.8 µm | Rz about 4.0–8.0 µm |
| Ra 1.6 µm | Rz about 8.0–16.0 µm |
| Rz 10 µm | Ra about 1.0–2.0 µm |
Source: NIST surface-calibration discussion. This is an order-of-magnitude model for approximately Gaussian random profiles, not a universal conversion table or a statistical confidence interval. If the drawing specifies Ra 0.8 µm, request an Ra result under the agreed measurement conditions; estimated Rz does not establish compliance.
When You’ll Use Ra ↔ Rz Conversion
- Check whether an Ra and Rz pair supplied by different parties is broadly plausible.
- Prepare a clarification request when a quotation and drawing use different parameters.
- Convert µm and µin without changing the parameter.
- Decide whether a direct measurement or process-specific correlation is required.
For stainless sheet finish designations such as 2B, BA, No.4, hairline and No.8, use the separate stainless steel surface finish chart.

How to Specify Surface Roughness Correctly (So You Avoid Disputes)
- Parameter and value: state Ra or Rz; do not write only “surface finish 0.8”.
- Unit: state µm or µin.
- Governing standard and edition: for example, the applicable ISO 21920 series or ASME B46.1 requirement.
- Measurement conditions: identify the agreed filtering/nesting index or cutoff, evaluation length, direction and instrument requirement where relevant.
- Acceptance: state the limit rule and sampling plan; do not substitute an estimated Ra/Rz value.
Example clarification: “Drawing states Ra 0.8 µm. Supplier report gives Rz only. Please confirm the governing surface-texture standard and provide Ra measurement under the agreed conditions; the Rz value will not be accepted as an exact conversion.”

Stainless Steel Supply and Surface Processing
Kongfang Metal supplies stainless steel materials with stock and processing services for your surface requirements. Send the form, dimensions, quantity, desired finish and any drawing or Ra/Rz requirement. Include the unit, measurement standard and inspection documents when roughness controls acceptance.
For flat-rolled products, see stainless steel sheet and plate and surface-finished stainless products. The governing specification and agreed supplier documentation take precedence over this estimator.
Technical references: ISO 21920-2:2021 and ASME B46.1-2019 (R2026).
FAQs
For common manufactured profiles, Rz is usually numerically larger than Ra, but the ratio is not fixed. Treat an unusual pair as a reason to confirm the data and measurement definition.
No. Exact conversion requires the original measured profile and the applicable parameter definitions. A multiplier is only an estimate.
It is the Rz/Ra range used here for approximately Gaussian random profiles, following the order-of-magnitude relationship discussed by NIST. It is not a universal conversion, a statistical confidence interval, or an acceptance rule. For periodic tool marks or other profiles, measure the parameter required by the drawing.
Parameter definitions and default measurement rules can differ between current and legacy standards. Naming the governing document prevents two parties from evaluating the same symbol in different ways.
State the required parameter, value or limit, unit, governing standard/edition, agreed measurement conditions and acceptance/sampling rule. If appearance also matters, specify it separately.